Back to research feed

The Journal of thoracic and cardiovascular surgery

May 4, 2026 · via Europe PMC

Virtual reality in planning complex heart surgery.

Maya HA, Kottayil BP, Pandey AK, +5 more, Kappanayil M.

Video-Audio MediaAbstract only — full text under license

AI summary — for doctors, generated from the abstract only

In a small prospective series, 3D virtual reality and 3D-printed baffle templates helped guide complex intraventricular tunneling repairs in congenital heart disease, with surgical outcomes matching the virtual plan and no operative mortality.

What was studied

A prospective study of 20 complex congenital heart disease cases (mean age 8.61 years) requiring biventricular or 1.5-ventricle repair with intraventricular tunneling, using CT-derived 3D virtual reality 'digital twins' and 3D-printed templates to plan and guide baffle placement during surgery.

Key findings

  • Repair was achieved in 100% of cases (2-ventricle repair in 14 patients, 1.5-ventricle repair in 6); virtual, 3D-printed, and paper-printed baffle templates matched each other with less than 10% deviation from predicted geometry.
  • All baffles were single-patch, placed according to the digital plan, with no residual defects noted intraoperatively.
  • Median hospital stay was 10 days, with no operative mortality and no reinterventions or residual lesions at a median 20-month follow-up.

Clinical relevance

The findings suggest virtual-reality-based planning and 3D-printed templates may be a feasible and accurate tool to guide complex congenital cardiac repairs, potentially supporting surgical decision-making in anatomically complex cases, though the authors describe this as 'early-stage exploration' of the technology's translational impact.

Who should care

CardiologyGeneral SurgeryPulmonary MedicineVascular Surgery

Limitations

This was a small (n=20), single-institution, uncontrolled series without a comparison group of patients treated without this technology, so any improvement in outcomes attributable specifically to the technology cannot be established.

Virtual reality and 3D-printed surgical templates accurately guided complex congenital heart repairs in this early feasibility series.

This is an AI-generated summary of the published abstract, not a clinical recommendation. It may not reflect the full text or subsequent updates — verify against the original source before acting on it.

Abstract

Objectives

Intraventricular tunneling is a pivotal step in biventricular or 1.5 ventricle repair of complex congenital heart disease, conventionally reliant on surgeon's intraoperative inspection and judgement. We evaluated novel assistive processes and translational tools for aiding intraventricular tunneling during complex surgical repairs using 3-dimensional virtual reality and 3-dimensional printing technologies.

Methods

Computed tomography data of prospective complex congenital heart disease cases considered for biventricular/1.5 ventricle repair with intraventricular tunneling were converted to "digital twins" and analyzed in 3-dimensional virtual reality using medical modeling software. Digital dissection, annotation, and measurement tools helped identify critical anatomic elements: interventricular septum to great vessel orientation, optimal pathway least likely to obstruct, dynamic changes, conduit requirement, and so forth. Virtual baffle design tool simulated baffles with morphometrics. Novel workflows helped convert virtual baffles to physical templates: 3-dimensionally printed in flexible resin, digitally unfolded and printed in rigid resin, and on plain paper. Templates were compared and used as surgical guides. Adherence to simulation-based plans and surgical baffle placement were assessed.

Results

Twenty cases (mean age 8.61 ± 7.61 years) included double outlet right ventricles (n = 12; 2 with superior-inferior ventricles, 2 with common atrioventricular canal), double outlet both ventricles (1), corrected transposition (5), and D-transposition (2) variants. Situs abnormalities (5/20), dextrocardia (7/20), and additional defects added to the complexity. Operative findings were as predicted, and repair was achieved in 100% (2 ventricle repair in 14 patients and 1.5 ventricle repair in 6 patients). Morphometrics of virtual, 3-dimensional printed, and paper-printed baffles were identical and successfully used as surgical guides; deviation from predicted geometry was less than 10%. All baffles were single patch, placed as per digital plan, with no residuals. Mean cardiopulmonary bypass time was 322 ± 109 minutes, and crossclamp time was 159 ± 54 minutes. Median hospital stay was 10 days (interquartile range, 8-16) with no operative mortality. No reinterventions or residuals were observed at 20 months median follow-up.

Conclusions

Early-stage exploration of translational impact of 3-dimensional virtual reality-based baffle planning is encouraging. Workflow for creating paper-printable baffle templates shows great promise.

DOI

10.1016/j.jtcvs.2026.03.616

PMID

42092499

Research metadata (titles, abstracts, authors, publication dates) is sourced from Europe PMC, which aggregates content from PubMed/MEDLINE, PubMed Central, and other providers under the U.S. National Library of Medicine (NLM/NCBI). NLM does not claim copyright on abstracts; the original journal publishers or authors may hold rights to the full articles. AI-generated summaries are derived only from the abstract, never the full text, and are always labeled as AI-generated.

Want more like this?

Browse more from the feed. A free account unlocks the full feed, saving and communities.

Back to the research feed

Create a free account · Sign in