Prehospital emergency care
October 6, 2026 ยท via Europe PMC
Bystander AED effectiveness despite low utilisation in OHCA.
Sohn Y, Cho G, Cho Y, Park T, Korean Cardiac Arrest Research Consortium (KoCARC) Investigators.
AI summary โ for doctors, generated from the abstract only
When bystanders did apply an AED in Korean out-of-hospital cardiac arrest, survival and neurological outcomes were better than with no defibrillation, but AEDs were rarely used, especially in residential settings.
What was studied
Retrospective analysis of a prospective multicentre Korean OHCA registry (October 2015 to June 2025; 23,918 adults of presumed medical cause) comparing bystander AED application (n = 383), EMS-delivered shock without bystander AED (n = 5,975) and no prehospital defibrillation as the reference (n = 17,560), using multivariable, propensity-score and weighted analyses.
Key findings
- Bystander AED was associated with improved survival to discharge (aOR 1.60; 95% CI 1.19-2.14) and good neurological outcome (aOR 2.31; 1.65-3.23) versus no defibrillation
- Using a pooled control group that mixed EMS-shocked and non-shocked patients shrank the estimates to non-significance (survival 1.09; neurological 1.14)
- Effectiveness did not differ by location (interaction P 0.15 or higher), but bystander AED was applied in 8.5% of public-area versus 1.9% of non-public opportunity cases, a 4.5-fold gap
Clinical relevance
The main barrier to benefit appears to be getting AEDs applied, not device effectiveness, particularly at home. The authors argue residential rapid-activation infrastructure deserves policy priority alongside continued device placement.
Who should care
Limitations
Observational registry data from one country, so residual confounding and selection of who receives a bystander AED cannot be excluded. Only 383 cases involved a bystander AED, limiting precision in subgroups.
Bystander AED use is associated with better outcomes when it happens; closing the deployment-to-use gap, especially in residences, is the priority.
This is an AI-generated summary of the published abstract, not a clinical recommendation. It may not reflect the full text or subsequent updates โ verify against the original source before acting on it.
Abstract
Objectives
Observational estimates of bystander automated external defibrillator (AED) effectiveness are inconsistent in settings with mature public-access defibrillation infrastructure but low utilisation, partly because the conventional reference group pools emergency medical services (EMS)-shocked with non-defibrillated patients. We estimated bystander AED effectiveness against a partitioned no-defibrillation reference, tested effect modification by location, and quantified the deployment-utilisation gap.
Methods
Retrospective analysis of a prospectively collected multicentre out-of-hospital cardiac arrest (OHCA) registry (Korea, October 2015-June 2025; 23,918 adults of presumed medical aetiology). A three-tier prehospital defibrillation-provider variable was defined: bystander AED applied (nโ=โ383); EMS-delivered shock without preceding bystander AED (nโ=โ5,975); and no prehospital defibrillation (reference; nโ=โ17,560). Primary outcomes were survival to discharge and good neurological outcome (Cerebral Performance Category 1-2), analysed by multivariable logistic regression with propensity-score, inverse-probability-weighting and location-stratified secondary analyses.
Results
Bystander AED application was associated with improved survival (adjusted odds ratio [aOR] 1.60; 95% CI 1.19-2.14) and good neurological outcome (2.31; 1.65-3.23), comparable to that of EMS-delivered shock; the pooled-control specification attenuated estimates to non-significance (survival 1.09; neurological 1.14). Shock-delivered applications significantly exceeded EMS-delivered shock for neurological outcome (aOR 1.43; Pโ=โ0.03). Effectiveness did not differ by location (interaction Pโโฅโ0.15). Bystander AED was applied in 8.5% of Public-area versus 1.9% of Non-public AED-opportunity cases - a 4.5-fold gap.
Conclusions
Bystander AED was associated with improved outcomes when applied, comparable to or exceeding EMS-delivered shock; the dominant constraint was the deployment-utilisation gap, greatest in residential settings. Residential rapid-activation infrastructure warrants policy priority alongside, not instead of, continued device placement.
DOI
10.1080/10903127.2026.2743854
PMID
42837514
Research metadata (titles, abstracts, authors, publication dates) is sourced from Europe PMC, which aggregates content from PubMed/MEDLINE, PubMed Central, and other providers under the U.S. National Library of Medicine (NLM/NCBI). NLM does not claim copyright on abstracts; the original journal publishers or authors may hold rights to the full articles. AI-generated summaries are derived only from the abstract, never the full text, and are always labeled as AI-generated.
Want more like this?
Browse more from the feed. A free account unlocks the full feed, saving and communities.
Back to the research feed