Back to research feed

Neurourology and urodynamics

October 13, 2026 · via Europe PMC

Standing or Sitting to Void? Comparative Uroflowmetry in Healthy Male Volunteers: A Randomized Crossover Study with Equivalence Analysis.

Iregui-Parra J, Millán-Serna S, Delgado-Caicedo MG, +6 more, Leal DMC.

Journal ArticleAbstract only — full text under license

AI summary — for doctors, generated from the abstract only

In healthy men, voiding posture did not significantly change maximum flow rate or volume, but equivalence for Qmax could not be proven.

What was studied

Randomized 2x2 crossover study of 52 healthy male volunteers (sitting-then-standing n = 24, standing-then-sitting n = 28, washout at least 24 hours) comparing uroflowmetry, with a TOST equivalence analysis for Qmax (margin 2.5 mL/s).

Key findings

  • Qmax did not differ (difference -1.47 mL/s; 95% CI -3.55 to 0.62; p = 0.164)
  • Total volume did not differ (difference -14.7 mL; p = 0.318)
  • Time to maximum flow was longer standing (+3.32 s; p = 0.011, remaining significant after correction)
  • The TOST for Qmax was not significant (p about 0.16), so equivalence was not established

Clinical relevance

Posture is unlikely to meaningfully alter uroflow in healthy men, though the small tQmax difference was partly outlier-driven; symptomatic populations may behave differently.

Who should care

Urology

Limitations

Healthy volunteers only, a modest sample that was underpowered for equivalence, and a tQmax finding partly dependent on a single outlier.

No meaningful posture effect was shown, but larger pre-registered studies in symptomatic men are needed.

This is an AI-generated summary of the published abstract, not a clinical recommendation. It may not reflect the full text or subsequent updates — verify against the original source before acting on it.

Abstract

Introduction

The posture adopted during voiding may influence uroflowmetric parameters, such as maximum urinary flow rate (Qmax), voided volume, and time to maximum flow (tQmax). Published studies have shown inconsistent results, and uncertainty persists regarding the clinical relevance of these differences in healthy men.

Objective

To compare uroflowmetric parameters during standing and sitting voiding in healthy male volunteers using a randomized crossover design, incorporating a formal equivalence analysis (Two One-Sided Tests, TOST) for the primary outcome (Qmax).

Material and methods

This prospective, randomized, 2 × 2 crossover study included 52 healthy male volunteers allocated to the sitting → standing (n = 24) or standing → sitting (n = 28) sequence, with a minimum washout period of 24 h. The primary outcome was Qmax and the secondary outcomes were the total voided volume and tQmax. Paired tests, correction for multiple comparisons (Bonferroni and Benjamini-Hochberg), linear mixed-effects models, Bayesian analysis, and TOST equivalence analysis for Qmax (margin ±2.5 mL/s) were used.

Results

Baseline characteristics were comparable between sequences. No significant differences between postures were observed for Qmax (Δ = -1.47 mL/s; 95% CI -3.55 to 0.62; p = 0.164) or for total volume (Δ = -14.7 mL; 95% CI -43.9 to 14.6; p = 0.318). The tQmax was longer while standing (Δ = +3.32 s; 95% CI 0.94 to 5.69; p = 0.011), remaining significant after Bonferroni correction (p = 0.031) and FDR correction (q = 0.031). The mixed models did not identify either sequence or period effects. Bayesian analysis showed moderate evidence in favor of a difference in tQmax (BF10 = 4.99) and in favor of no difference in volume (BF01 = 4.10). The equivalence analysis (TOST) for Qmax was not significant (p-TOST ≈ 0.16); therefore, the equivalence of the maximum flow between postures could not be formally claimed with the present sample size.

Conclusions

In healthy men, voiding posture did not significantly modify the maximum urinary flow rate or voided volume; however, formal equivalence of Qmax was not demonstrated. The sitting position was associated with a shorter time to maximum flow, a small difference that is unlikely to be clinically meaningful and was partly dependent on a single outlier. Larger, pre-registered studies with pre-specified equivalence analyses and symptomatic populations are required.

DOI

10.1002/nau.70485

PMID

42865243

Research metadata (titles, abstracts, authors, publication dates) is sourced from Europe PMC, which aggregates content from PubMed/MEDLINE, PubMed Central, and other providers under the U.S. National Library of Medicine (NLM/NCBI). NLM does not claim copyright on abstracts; the original journal publishers or authors may hold rights to the full articles. AI-generated summaries are derived only from the abstract, never the full text, and are always labeled as AI-generated.

Want more like this?

Browse more from the feed. A free account unlocks the full feed, saving and communities.

Back to the research feed

Create a free account · Sign in