Back to research feed

Clinical oncology (Royal College of Radiologists (Great Britain))

October 1, 2026 · via Europe PMC

Respiratory Instability-driven Cardiac Dose Deviation in Postmastectomy Deep Inspiration Breath-hold Volumetric Modulated Arc Therapy (DIBH VMAT): Development and External Validation of a Respiratory-informed Predictive Framework.

Singh S, Sen S, Singh AK, +5 more, Chufal KS.

Journal ArticleAbstract only — full text under license

AI summary — for doctors, generated from the abstract only

A model using treatment-day breathing and anatomical features can estimate fraction-level cardiac dose deviations in left breast DIBH radiotherapy, with better accuracy for mean heart dose than for LAD dose.

What was studied

Retrospective study of 150 postmastectomy DIBH VMAT patients: model development in 30, external validation in 20 using CBCT-derived synthetic CT, and application to 100 patients, predicting deviation in mean heart dose and LAD dose.

Key findings

  • Mean heart dose deviation model had internal MAE 0.541 cGy (R2 0.642) and external MAE 0.58 cGy (R2 0.641).
  • LAD dose deviation was predicted less well, with external MAE 24.14 cGy and R2 0.435.
  • Breathing stability index and baseline drift were key predictors.

Clinical relevance

Could help flag fractions where heart dose may exceed plan because of poor breath-hold reproducibility.

Who should care

Radiation Oncology

Limitations

Small development and validation cohorts from retrospective data, with only moderate explanatory power, especially for LAD dose.

Do not use clinically yet; the authors say further validation is needed, but breath-hold stability is worth monitoring.

This is an AI-generated summary of the published abstract, not a clinical recommendation. It may not reflect the full text or subsequent updates — verify against the original source before acting on it.

Abstract

Aims

Deep inspiration breath-hold (DIBH) reduces cardiac exposure during left-sided breast radiotherapy; however, treatment-day cardiac dose may differ from the planned dose because of variations in respiratory reproducibility and anatomy. The aim of this study was to develop and validate a framework for predicting fraction-level cardiac dose variation using routinely acquired respiratory, anatomical, and dosimetric information.

Materials and methods

A retrospective cohort of 150 patients treated with postmastectomy DIBH VMAT (volumetric modulated arc therapy) was analyzed. Models were developed using a 30-patient development cohort with patient-wise-nested cross-validation, externally validated in 20 independent patients using cone-beam CT-derived synthetic CT dose recalculation, and applied to a 100-patient deployment cohort. Separate models predicted deviation from planned per-fraction mean heart dose (ΔMHD) and left anterior descending coronary artery dose (ΔLADCA D0.03 cc) using treatment-day real-time position management (RPM)--derived respiratory features, planning computed tomography (CT)-derived geometric variables, and plan-derived dosimetric parameters. SHAP-based analysis was performed to identify influential predictors.

Results

The final Gradient Boosting model for ΔMHD achieved an internal validation mean absolute error (MAE) of 0.541 ± 0.035 centigray (cGy) and coefficient of determination (R2) of 0.642 ± 0.069. The Ridge Regression model for left anterior descending coronary artery (ΔLADCA) achieved an MAE of 23.413 ± 1.617 cGy and R2 of 0.413 ± 0.082. External validation demonstrated good agreement for ΔMHD (MAE 0.58 cGy, R2 = 0.641), whereas ΔLADCA showed lower performance (MAE 24.14 cGy, R2 = 0.435). Stability index and baseline drift were key predictors.

Conclusion

Treatment-day-respiratory characteristics combined with anatomical and dosimetric variables can estimate fraction-level cardiac dose variation during DIBH radiotherapy. The framework may support verification-based clinical review, with further validation required before implementation.

DOI

10.1016/j.clon.2026.104353

PMID

42913341

Research metadata (titles, abstracts, authors, publication dates) is sourced from Europe PMC, which aggregates content from PubMed/MEDLINE, PubMed Central, and other providers under the U.S. National Library of Medicine (NLM/NCBI). NLM does not claim copyright on abstracts; the original journal publishers or authors may hold rights to the full articles. AI-generated summaries are derived only from the abstract, never the full text, and are always labeled as AI-generated.

Want more like this?

Browse more from the feed. A free account unlocks the full feed, saving and communities.

Back to the research feed

Create a free account · Sign in