Pediatric cardiology
January 6, 2026 Β· via Europe PMC
4D Flow Yields Similar Clinical Results Compared To 2D Phase Contrast for Decision Making Regarding Pulmonary Valve Replacement in Repaired Tetralogy of Fallot.
Almgren-Bell A, Popescu A, Sodhi A, Markl M, Rigsby CK, Robinson JD.
AI summary β for doctors, generated from the abstract only
4D flow MRI measured pulmonary regurgitation about as well as 2D phase contrast and led to similar pulmonary valve replacement decisions in repaired tetralogy of Fallot.
What was studied
Retrospective study of 33 repaired tetralogy of Fallot patients with standard CMR plus 4D flow, comparing regurgitant fraction by 2D phase contrast, 4D flow and volumetric methods and the resulting intervention decisions.
Key findings
- Regurgitant fraction correlated strongly between 2D and 4D flow (r = 0.87) and 4D flow with volumetric analysis (r = 0.81).
- Mean difference between 2D and 4D flow was -3.76% (ICC 0.83).
- Decision agreement was moderate (kappa 0.58) using flow only and strong (0.76) when volumetric regurgitation was added.
Clinical relevance
4D flow can be trusted for pulmonary regurgitation quantification, and could eventually shorten CMR exams in tetralogy follow-up.
Who should care
Limitations
Small single-center retrospective sample with decisions made by a standardized algorithm rather than actual clinical outcomes.
You can use 4D flow regurgitant fraction in PVR decision-making, ideally with ventricular volumes, until 4D volumetrics are validated.
This is an AI-generated summary of the published abstract, not a clinical recommendation. It may not reflect the full text or subsequent updates β verify against the original source before acting on it.
Abstract
2D phase contrast (PC) CMR is critical for monitoring pulmonary regurgitant fraction (PRF) in patients with a history of repaired tetralogy of Fallot (rTOF) and guides decisions about pulmonary valve replacement (PVR). However, newer techniques such as 3D time-resolved phase contrast (4D flow) MRI are gaining momentum due to the added clinical value beyond conventional flow metrics. While agreement between 2D PC CMR and 4D flow is well-established, the real-world implications for clinical decision-making have not been fully studied and are thus the primary aim of this study. All patients with rTOF who underwent standard CMR plus retrospectively gated 4D flow between February 2021 - June 2023 were identified. Clinical information was collected from the electronic medical record (EMR). 2D cine steady-state free procession (SSFP), PC data, and 4D flow imaging data were analyzed using standard post-processing analysis. Clinical decisions ("intervention vs. no intervention") were determined using a standardized algorithm, and inter-rater agreement was assessed using the intra-class coefficient (ICC) and the [Formula: see text] coefficient. 33 patients were included. PRF correlated strongly between 2D PC and 4D flow (rβ=β0.87, rs = 0.89) and between 4D flow and volumetric SSFP analysis (rβ=β0.81, rs = 0.79). The mean absolute difference between 2D and 4D PRF was -β3.76% (95% CI [-6.91, -0.60]) with an ICC of 0.83. Inter-rater agreement for the decision was moderate ([Formula: see text]=0.58) using only PRF calculated only using 2D PC and 4D flow, and was strong ([Formula: see text]=0.76) when using PRF calculated by 2D PC and 4D flow with volumetric PRF. Though clinical indications for PVR in rTOF vary, 4D flow generates accurate measurements of PRF and yields similar clinical decisions about intervention in rTOF. Future studies exploring ventricular volume assessment by 4D flow could potentially eliminate the need for cine SSFP acquisitions and lead to a shorter, more comprehensive CMR exam for TOF patients.
2D phase contrast (PC) CMR is critical for monitoring pulmonary regurgitant fraction (PRF) in patients with a history of repaired tetralogy of Fallot (rTOF) and guides decisions about pulmonary valve replacement (PVR). However, newer techniques such as 3D time-resolved phase contrast (4D flow) MRI are gaining momentum due to the added clinical value beyond conventional flow metrics. While agreement between 2D PC CMR and 4D flow is well-established, the real-world implications for clinical decision-making have not been fully studied and are thus the primary aim of this study. All patients with rTOF who underwent standard CMR plus retrospectively gated 4D flow between February 2021 - June 2023 were identified. Clinical information was collected from the electronic medical record (EMR). 2D cine steady-state free procession (SSFP), PC data, and 4D flow imaging data were analyzed using standard post-processing analysis. Clinical decisions ("intervention vs. no intervention") were determined using a standardized algorithm, and inter-rater agreement was assessed using the intra-class coefficient (ICC) and the [Formula: see text] coefficient. 33 patients were included. PRF correlated strongly between 2D PC and 4D flow (rβ=β0.87, rs = 0.89) and between 4D flow and volumetric SSFP analysis (rβ=β0.81, rs = 0.79). The mean absolute difference between 2D and 4D PRF was -β3.76% (95% CI [-6.91, -0.60]) with an ICC of 0.83. Inter-rater agreement for the decision was moderate ([Formula: see text]=0.58) using only PRF calculated only using 2D PC and 4D flow, and was strong ([Formula: see text]=0.76) when using PRF calculated by 2D PC and 4D flow with volumetric PRF. Though clinical indications for PVR in rTOF vary, 4D flow generates accurate measurements of PRF and yields similar clinical decisions about intervention in rTOF. Future studies exploring ventricular volume assessment by 4D flow could potentially eliminate the need for cine SSFP acquisitions and lead to a shorter, more comprehensive CMR exam for TOF patients.
DOI
10.1007/s00246-025-04146-3
PMID
41493464
PMCID
PMC13687135
Research metadata (titles, abstracts, authors, publication dates) is sourced from Europe PMC, which aggregates content from PubMed/MEDLINE, PubMed Central, and other providers under the U.S. National Library of Medicine (NLM/NCBI). NLM does not claim copyright on abstracts; the original journal publishers or authors may hold rights to the full articles. AI-generated summaries are derived only from the abstract, never the full text, and are always labeled as AI-generated.
Want more like this?
Browse more from the feed. A free account unlocks the full feed, saving and communities.